Energy Use Modeling
Helpful Links
Asset and Portfolio Analysis
SRI/EPC Estimator
EnergyPlus
The energy use data embedded in the Impact Building Calculator is modeled with the physics-based EnergyPlus whole building energy simulation engine supplemented by a machine learning algorithm. Simulations were performed using the Existing Commercial Reference Buildings Constructed In or After 1980 (v1.4) provided by the United States Department of Energy. Simulations were performed for every possible combination of ECCMs available in the Building Decarbonization Calculator within each Building Segment, across all representative climate zones.
Results of these simulations were normalized by unit gross floor area. When asset data is entered in the Calculator, the area-normalized data is scaled to the user input.
End Use
In the context of energy consumption, "end use" refers to the specific category or application where energy is utilized within a building or system. End use breaks down total energy use into individual functions, such as heating, cooling, lighting, or equipment operation. Understanding end uses helps identify where energy is consumed most and informs targeted energy efficiency measures for each category.
Characteristics of Prototype Models
The following is a summary of the characteristics of the prototype models used in the analysis. Where available prototype models were used rather than custom created, the full model documentation and the models themselves are available from the US Department of Energy Office of Energy Efficiency and Renewable Energy.
| Use Category | Conditioned GFA | Window-to-Wall Ratio |
| Hospital (built before 2000) | 564,400 sf | 16% |
| Hospital (built after 2000) | 241,410 sf | 16% |
| Hotel (small) | 43,200 sf | 11% |
| Hotel (large) | 122,132 sf | 30% |
| Office (small) | 5,500 sf | 21% |
| Office (medium) | 53,600 sf | 33% |
| Office (large) | 498,600 sf | 40% |
| Supermarket | 45,006 sf | 7% |
| Urban Grocery* | 5,000 sf | 15% |
| Storefront Retail | 3,200 sf | 15% |
| Warehouse | 52,000 sf | 1% |
| Refrigerated Warehouse* | 215,200 sf | 1% |
| Quick Service Restaurant | 2,500 sf | 14% |
| Mixed Use Super Tall Building* | 821,791 sf | 58% |
| Dormitory* | 40,000 sf | 30% |
* The urban grocery, refrigerated warehouse, mixed-use super tall building, and dormitory prototype models were created for this tool only and are not DoE-supplied models.
Typical Baseline Systems
USA & AUS & CAN
| Use Category | Baseline HVAC Systems |
| Hospital | Hot water system with gas boilers; Chilled water system with water-cooled chillers and open cooling tower; Floor-by-floor VAV AHUs with hot water reheat and steam humidifiers; Central service water heaters - gas-fired |
| Hotel (small) | Packages terminal air conditioner with electric heating; Packaged rooftop air conditioner or Packaged rooftop air conditioner with two fan speed (Size dependent); Warm air furnace, electric |
| Hotel (large) | Hot water system with gas boilers; Chilled water system with air-cooled chillers; Guest rooms: four-pipe fan coils; Public spaces: VAV with hot water reheat; Central service water heaters - gas-fired |
| Office (small) | Packaged rooftop heat pump with gas auxiliary heat |
| Office (medium) | Packaged air conditioning unit with gas-fired heating; Distribution via Variable Air Volume (VAV) terminals with electric reheat; Service water heaters - gas-fired |
| Office (large) | Hot water system with a gas boiler; Chilled water system with water-cooled chillers and open cooling tower; Fluid coolers for data centers; Distribution via VAV terminals with hot water reheat; Service water heaters - gas-fired |
| Supermarket | Packaged single-zone rooftop units with DX cooling and gas-fired furnaces; Service water heaters - gas-fired |
| Urban Grocery | Packaged central unit, pPackaged rooftop units (RTUs), Centralized water heater - gas-fired |
| Storefront Retail | Packaged RTUs equipped with an electric DX coil for cooling and gas furnace for heating, Gas water heaters |
| Warehouse | Packaged single-zone RTUs, Instantaneous electric water heater |
| Refrigerated Warehouse | Packaged RTUs for office and loading, Instantaneous electric water heater, Central cooling system with screw compressors and evaporator units for cooler/freezer storage areas |
| Quick Service Restaurant | Packaged single-zone RTUs, Natural gas water heater |
| Mixed Use Super Tall Building | Centralized hydronic plant with natural gas boilers and water-cooled chillers, Floor-by-floor VAV AHUs for office, retail, and hotel common spaces. DOAS supplying OA to each AHU, Fan coil + DOAS for hotel guest rooms, Natural gas water heaters (multi-zone distribution) |
| Dormitory | Fan coil units with a makeup air unit and district cooling and heating, Centralized natural gas-fired boiler system |
EU & UK
| Use Category | Baseline HVAC Systems |
| Hospital | Fan coil units with gas boilers and water-cooled chillers; Dedicated Outside Air System (DOAS) with hydronic heating and cooling coils |
| Hotel (small) | Packages terminal air conditioner with electric heating; Packaged rooftop air conditioner or Packaged rooftop air conditioner with two fan speed (Size dependent); Warm air furnace, electric |
| Hotel (large) | Hot water system with gas boilers; Chilled water system with air-cooled chillers; Guest rooms: four-pipe fan coils; Public spaces: VAV with hot water reheat; Central service water heaters - gas-fired |
| Office (small) | Packaged rooftop heat pump with gas auxiliary heat |
| Office (medium | Packaged air conditioning unit with gas-fired heating; Distribution via Variable Air Volume (VAV) terminals with electric reheat; Service water heaters - gas-fired |
| Office (large) | Hot water system with a gas boiler; Chilled water system with water-cooled chillers and open cooling tower; Fluid coolers for data centers; Distribution via VAV terminals with hot water reheat; Service water heaters - gas-fired |
| Supermarket | Packaged single-zone rooftop units with DX cooling and gas-fired furnaces; Service water heaters - gas-fired; Air-to-air heat recovery in all Northern European locations |
| Urban Grocery | Packaged central unit, pPackaged rooftop units (RTUs), Centralized water heater - gas-fired |
| Storefront Retail | Packaged RTUs equipped with an electric DX coil for cooling and gas furnace for heating, Gas water heaters |
| Warehouse | Packaged single-zone RTUs, Instantaneous electric water heater |
| Refrigerated Warehouse | Packaged RTUs for office and loading, Instantaneous electric water heater, Central cooling system with screw compressors and evaporator units for cooler/freezer storage areas |
| Quick Service Restaurant | Packaged single-zone RTUs, Natural gas water heater |
| Mixed Use Super Tall Building | Centralized hydronic plant with natural gas boilers and water-cooled chillers, Floor-by-floor VAV AHUs for office, retail, and hotel common spaces. DOAS supplying OA to each AHU, Fan coil + DOAS for hotel guest rooms, Natural gas water heaters (multi-zone distribution) |
| Dormitory | Fan coil units with a makeup air unit and district cooling and heating, Centralized natural gas-fired boiler system |
Singapore and Hong Kong
| Use Category | Baseline HVAC Systems |
| Hospital | Fan coil units with hydronic coils served by water-cooled chillers; Dedicated Outside Air System (DOAS) with hydronic heating and cooling coils; Demand Control Ventilation was assumed when built after 2000; No airside heat/energy recovery |
| Hotel (small) | Packages terminal air conditioner with electric heating; Packaged rooftop air conditioner or Packaged rooftop air conditioner with two fan speed (Size dependent); Warm air furnace, electric; No airside heat/energy recovery |
| Hotel (large) | Hot water system with gas boilers; Chilled water system with air-cooled chillers; Guest rooms: four-pipe fan coils; Public spaces: VAV with hot water reheat; Central service water heaters - gas-fired; No airside heat/energy recovery |
| Office (small) | Packaged rooftop heat pump with gas auxiliary heat |
| Office (medium) | Packaged air conditioning unit with gas-fired heating; Distribution via Variable Air Volume (VAV) terminals with electric reheat; Service water heaters - gas-fired; No Demand Control Ventilation when built after 2000 |
| Office (large) | Hot water system with a gas boiler; Chilled water system with water-cooled chillers and open cooling tower; Fluid coolers for data centers; Distribution via VAV terminals with hot water reheat; Service water heaters - gas-fired; No Demand Control Ventilation when built after 2000; Energy recovery wheels on all air handling units |
| Supermarket | Packaged single-zone rooftop units with DX cooling and gas-fired furnaces; Service water heaters - gas-fired |
| Urban Grocery | Packaged central unit, pPackaged rooftop units (RTUs), Centralized water heater - gas-fired |
| Storefront Retail | Packaged RTUs equipped with an electric DX coil for cooling and gas furnace for heating, Gas water heaters |
| Warehouse | Packaged single-zone RTUs, Instantaneous electric water heater |
| Refrigerated Warehouse | Packaged RTUs for office and loading, Instantaneous electric water heater, Central cooling system with screw compressors and evaporator units for cooler/freezer storage areas |
| Quick Service Restaurant | Packaged single-zone RTUs, Natural gas water heater |
| Mixed Use Super Tall Building | Centralized hydronic plant with natural gas boilers and water-cooled chillers, Floor-by-floor VAV AHUs for office, retail, and hotel common spaces. DOAS supplying OA to each AHU, Fan coil + DOAS for hotel guest rooms, Natural gas water heaters (multi-zone distribution) |
| Dormitory | Fan coil units with a makeup air unit and district cooling and heating, Centralized natural gas-fired boiler system |
UAE
| Use Category | Baseline HVAC Systems |
| Hospital | Hot water system with gas boilers; Air-cooled chillers when built before 2000, and district cooling system when built after 2000; Floor-by-floor VAV AHUs with hot water reheat and steam humidifiers; Central service water heaters - gas-fired; No energy recovery |
| Hotel (small) | Packages terminal air conditioner with electric heating; Packaged rooftop air conditioner or Packaged rooftop air conditioner with two fan speed (Size dependent); Warm air furnace, electric; No energy recovery |
| Hotel (large) | Hot water system with gas boilers; Chilled water system with air-cooled chillers; Guest rooms: four-pipe fan coils; Public spaces: VAV with hot water reheat; Central service water heaters - gas-fired; No energy recovery |
| Office (small) | Packaged rooftop heat pump with gas auxiliary heat; No energy recovery |
| Office (medium) | Packaged air conditioning unit with gas-fired heating; Distribution via Variable Air Volume (VAV) terminals with electric reheat; Service water heaters - gas-fired |
| Office (large) | Hot water system with a gas boiler; water-cooled chillers when built before 2000, and air-cooled chillers when built after 2000; Fluid coolers for data centers; Single-zone packaged split air conditioners when built before 2000, and distribution via Variable Air Volume (VAV) terminals with electric reheat when built after 2000; Service water heaters - gas-fired; No energy recovery |
| Supermarket | Packaged single-zone rooftop units with DX cooling and gas-fired furnaces; Service water heaters - gas-fired; No energy recovery |
| Urban Grocery | Packaged central unit, pPackaged rooftop units (RTUs), Centralized water heater - gas-fired |
| Storefront Retail | Packaged RTUs equipped with an electric DX coil for cooling and gas furnace for heating, Gas water heaters |
| Warehouse | Packaged single-zone RTUs, Instantaneous electric water heater |
| Refrigerated Warehouse | Packaged RTUs for office and loading, Instantaneous electric water heater, Central cooling system with screw compressors and evaporator units for cooler/freezer storage areas |
| Quick Service Restaurant | Packaged single-zone RTUs, Natural gas water heater |
| Mixed Use Super Tall Building | Centralized hydronic plant with natural gas boilers and water-cooled chillers, Floor-by-floor VAV AHUs for office, retail, and hotel common spaces. DOAS supplying OA to each AHU, Fan coil + DOAS for hotel guest rooms, Natural gas water heaters (multi-zone distribution) |
| Dormitory | Fan coil units with a makeup air unit and district cooling and heating, Centralized natural gas-fired boiler system |
Saudi Arabia
| Use Category | Baseline HVAC Systems |
| Hospital | Hot water system with gas boilers; Chilled water system with air-cooled chillers and open cooling tower; Floor-by-floor VAV AHUs with hot water reheat and steam humidifiers; Central service water heaters - gas-fired; No energy recovery |
| Hotel (small) | Packages terminal air conditioner with electric heating; Packaged rooftop air conditioner or Packaged rooftop air conditioner with two fan speed (Size dependent); Warm air furnace, electric; No energy recovery |
| Hotel (large) | Hot water system with gas boilers; Chilled water system with air-cooled chillers; Guest rooms: four-pipe fan coils; Public spaces: VAV with hot water reheat; Central service water heaters - gas-fired; No energy recovery |
| Office (small) | Packaged rooftop heat pump with gas auxiliary heat; No energy recovery |
| Office (medium) | Packaged air conditioning unit with gas-fired heating; Distribution via Variable Air Volume (VAV) terminals with electric reheat; Service water heaters - gas-fired; No energy recovery |
| Office (large) | Hot water system with a gas boiler; water-cooled chillers when built before 2000, and air-cooled chillers when built after 2000; Fluid coolers for data centers; Single-zone packaged split air conditioners when built before 2000, and distribution via Variable Air Volume (VAV) terminals with electric reheat when built after 2000; Service water heaters - gas-fired; No energy recovery |
| Supermarket | Packaged single-zone rooftop units with DX cooling and gas-fired furnaces; Service water heaters - gas-fired; No energy recovery |
| Urban Grocery | Packaged central unit, pPackaged rooftop units (RTUs), Centralized water heater - gas-fired |
| Storefront Retail | Packaged RTUs equipped with an electric DX coil for cooling and gas furnace for heating, Gas water heaters |
| Warehouse | Packaged single-zone RTUs, Instantaneous electric water heater |
| Refrigerated Warehouse | Packaged RTUs for office and loading, Instantaneous electric water heater, Central cooling system with screw compressors and evaporator units for cooler/freezer storage areas |
| Quick Service Restaurant | Packaged single-zone RTUs, Natural gas water heater |
| Mixed Use Super Tall Building | Centralized hydronic plant with natural gas boilers and water-cooled chillers, Floor-by-floor VAV AHUs for office, retail, and hotel common spaces. DOAS supplying OA to each AHU, Fan coil + DOAS for hotel guest rooms, Natural gas water heaters (multi-zone distribution) |
| Dormitory | Fan coil units with a makeup air unit and district cooling and heating, Centralized natural gas-fired boiler system |
Argentina & Chile
| Use Category | Baseline HVAC Systems |
| Hospital | Hot water system with gas boilers; Chilled water system with water-cooled chillers and open cooling tower; Floor-by-floor VAV AHUs with hot water reheat and steam humidifiers; Central service water heaters - gas-fired |
| Hotel (small) | Packages terminal air conditioner with electric heating; Packaged rooftop air conditioner or packaged rooftop air conditioner with two fan speed; Warm air furnace, electric |
| Hotel (large) | Hot water system with gas boilers; Chilled water system with air-cooled chillers; Guest rooms: four-pipe fan coils; Public spaces: VAV with hot water reheat; Central service water heaters - gas-fired |
| Office (small) | Packaged rooftop heat pump with gas auxiliary heat |
| Office (medium) | Packaged air conditioning unit with gas-fired heating; Distribution via VAV terminals with electric reheat; Service water heaters - gas-fired |
| Office (large) | Hot water system with gas boiler; Chilled water system with water-cooled chillers and open cooling tower; Fluid coolers for data centers; Distribution via VAV terminals with hot water reheat; Service water heaters - gas-fired |
| Supermarket | Packaged single-zone rooftop units with DX cooling and gas-fired furnaces; Service water heaters - gas-fired |
| Urban Grocery | Packaged central unit; Packaged rooftop units (RTUs); Centralized water heater |
| Storefront Retail | Packaged rooftop units (RTUs), equipped with electric DX coil for cooling and fossil fuel furnace for heating |
| Warehouse | Packaged single-zone rooftop units (RTUs); Instantaneous electric water heater |
| Refrigerated Warehouse | Packaged rooftop units (RTUs) serving office spaces and loading areas; Instantaneous electric water heater; Central cooling system with screw compressors and evaporator units for cooler/freezer storage |
| Quick Service Restaurant | Packaged single-zone rooftop units (RTUs); Natural gas water heater |
| Mixed Use Super Tall Building | Centralized hydronic plant with natural gas boilers and water-cooled chillers; Floor-by-floor VAV AHUs for office, retail, and hotel common spaces; DOAS supplying OA to each AHU; Fan coil + DOAS for hotel guest rooms; Natural gas water heaters (electric per modifications) |
| Dormitory | Fan coil units with makeup air unit and district cooling and heating; Centralized natural gas-fired boiler system |
Brazil
| Use Category | Baseline HVAC Systems |
| Hospital | Hot water system with gas boilers; Chilled water system with water-cooled chillers and open cooling tower; Floor-by-floor VAV AHUs with hot water reheat and steam humidifiers; Central service water heaters - gas-fired |
| Hotel (small) | Packages terminal air conditioner with electric heating; Packaged rooftop air conditioner or packaged rooftop air conditioner with two fan speed; Warm air furnace, electric; No wall insulation in zones 0-1 |
| Hotel (large) | Hot water system with gas boilers; Chilled water system with air-cooled chillers; Guest rooms: four-pipe fan coils; Public spaces: VAV with hot water reheat; Central service water heaters - gas-fired; No wall insulation in zones 0-1 |
| Office (small) | Packaged rooftop heat pump with gas auxiliary heat; Electric water heaters; Heating coils always off in zones 0-1; No wall insulation in zones 0-1 |
| Office (medium) | Packaged air conditioning unit with gas-fired heating; Distribution via VAV terminals with electric reheat; Electric water heaters; Heating coils always off in zones 0-1; No wall insulation in zones 0-1 |
| Office (large) | Hot water system with gas boiler; Chilled water system with water-cooled chillers and open cooling tower; Fluid coolers for data centers; Distribution via VAV terminals with hot water reheat; Electric water heaters; Heating coils always off in zones 0-1; No wall insulation in zones 0-1 |
| Supermarket | Packaged single-zone rooftop units with DX cooling and gas-fired furnaces; Service water heaters - gas-fired |
| Urban Grocery | Packaged central unit; Packaged rooftop units (RTUs); Electric water heaters; No wall insulation in zones 0-1 |
| Storefront Retail | Packaged rooftop units (RTUs), equipped with electric DX coil for cooling and fossil fuel furnace for heating; Electric water heaters; Heating coils always off in zones 0-1 |
| Warehouse | Packaged single-zone rooftop units (RTUs); Electric water heaters; Heating coils always off in zones 0-1; No wall insulation in zones 0-1 |
| Refrigerated Warehouse | Packaged rooftop units (RTUs) serving office spaces and loading areas; Electric water heaters; Central cooling system with screw compressors and evaporator units for cooler/freezer storage; Heating coils always off in zones 0-1; No wall insulation in zones 0-1 |
| Quick Service Restaurant | Packaged single-zone rooftop units (RTUs); Electric water heaters; Heating coils always off in zones 0-1 |
| Mixed Use Super Tall Building | Centralized hydronic plant with natural gas boilers and water-cooled chillers; Floor-by-floor VAV AHUs for office, retail, and hotel common spaces; DOAS supplying OA to each AHU; Fan coil + DOAS for hotel guest rooms; Electric water heaters; Heating coils always off in zones 0-1 |
| Dormitory | Fan coil units with makeup air unit and district cooling and heating; Centralized natural gas-fired boiler system; Electric water heaters; Heating coils always off in zones 0-1; No wall insulation in zones 0-1 |
India
| Use Category | Baseline HVAC Systems |
| Hospital | Hot water system with gas boilers; Chilled water system with water-cooled chillers and open cooling tower; Floor-by-floor VAV AHUs with hot water reheat and steam humidifiers; Electric water heaters; Energy recovery; Heating coils always off in zones 0-1 |
| Hotel (small) | Packages terminal air conditioner with electric heating; Packaged rooftop air conditioner or packaged rooftop air conditioner with two fan speed; Warm air furnace, electric; Electric water heaters; Heating coils always off in zones 0-1; No wall insulation in zones 0-1 |
| Hotel (large) | Hot water system with electric boilers; Chilled water system with air-cooled chillers; Guest rooms: four-pipe fan coils; Public spaces: VAV with hot water reheat; Electric water heaters; Energy recovery; Heating coils always off in zones 0-1; No wall insulation in zones 0-1 |
| Office (small) | Packaged rooftop heat pump with gas auxiliary heat; No SHW energy; Heating coils always off in zones 0-1; No wall insulation in zones 0-1 |
| Office (medium) | Packaged air conditioning unit with electric heating; Distribution via VAV terminals with electric reheat; No SHW energy; Heating coils always off in zones 0-1; No wall insulation in zones 0-1 |
| Office (large) | Hot water system with electric boiler; Chilled water system with water-cooled chillers and open cooling tower; Fluid coolers for data centers; Distribution via VAV terminals with hot water reheat; Electric water heaters; Energy recovery; Heating coils always off in zones 0-1 |
| Supermarket | Packaged single-zone rooftop units with DX cooling and electric furnaces; Electric water heaters; Heating coils always off in zones 0-1; No wall insulation in zones 0-1 |
| Urban Grocery | Packaged central unit; Packaged rooftop units (RTUs); Electric water heaters; No wall insulation in zones 0-1 |
| Storefront Retail | Packaged rooftop units (RTUs), equipped with electric DX coil for cooling and electric furnace for heating; No SHW energy; Heating coils always off in zones 0-1; No wall insulation in zones 0-1 |
| Warehouse | Packaged single-zone rooftop units (RTUs); Instantaneous electric water heater; Heating coils always off in zones 0-1; No wall insulation in zones 0-1 |
| Refrigerated Warehouse | Packaged rooftop units (RTUs) serving office spaces and loading areas; Instantaneous electric water heater; Central cooling system with screw compressors and evaporator units for cooler/freezer storage; Heating coils always off in zones 0-1; No wall insulation in zones 0-1 |
| Quick Service Restaurant | Packaged single-zone rooftop units (RTUs); No SHW energy; Heating coils always off in zones 0-1; No wall insulation in zones 0-1 |
| Mixed Use Super Tall Building | Centralized hydronic plant with electric boilers and water-cooled chillers; Floor-by-floor VAV AHUs for office, retail, and hotel common spaces; DOAS supplying OA to each AHU; Fan coil + DOAS for hotel guest rooms; Electric water heaters; Heating coils always off in zones 0-1 |
| Dormitory | Split heat pumps/ACs; Electric water heaters; Heating coils always off in zones 0-1; No wall insulation in zones 0-1 |
Representative Locations and Climate Zones
To fill in the location-specific climate data required for analysis, the Impact Building Calculator pairs a user's selected location with a representative location that is complete with ASHRAE climate zone data. Matching between selected and representative locations is completed using the following order of operations:
- First: the Calculator looks for the geographically closest representative city with the same climate zone. This matching type is considered a "Good match".
- Second: when there are no matching climate zones in proximity, the Calculator looks for a similar climate zones in the selected country. If multiple exist, the asset is matched with the similar representative location that is geographically-closest. This matching type is considered a "Decent Match".
- Third: when there are no similar climate zones in proximity, the Calculator will indicate the selected city is a poor match for the Calculator.
The following is the list of the representative cities for each ASHRAE Climate Zone modeled in the Calculator. More data on the ASHRAE Climate Zones is available online (pdf).
USA & AUS & CAN
Australia
- 2A – Brisbane
- 3A – Sydney
- 3B – Adelaide
Canada
- 4C – Vancouver
- 5A – Toronto
- 6A – Montreal
- 7 – Calgary
USA
- 1A – Miami, FL
- 1B – Phoenix, AZ
- 2A – Houston and Dallas, TX; Jacksonville and Orlando, FL
- 2B – Tucson, AZ; Las Vegas, NV
- 3A – Atlanta, GA; Memphis and Nashville, TN; Raleigh, NC
- 3B – El Paso, TX; Las Vegas, NV
- 3C – Los Angeles and San Francisco, CA
- 4A – Baltimore, MD; Nashville, TN; Louisville, KY; Wichita, KS; New York City, NY; Philadelphia, PA; Washington, DC
- 4B – Albuquerque, NM
- 4C – Seattle, WA; Portland, OR
- 5A – Chicago, IL; Boston, MA; Omaha, NE; Des Moines, IA
- 5B – Boulder, CO; Boise, ID; Salt Lake City, UT
- 5C – Bremerton, WA
- 6A – Minneapolis, MN; Burlington, VT
- 6B – Helena, MT
- 7 – Duluth, MN
EU & UK
Belgium
- 4A – Brussels
Denmark
- 5A – Copenhagen
France
- 3A – Bordeaux
- 4A – Paris
- 5A – Belfort
Finland
- 6A – Helsinki
Germany
- 4A – Frankfurt
- 5A – Berlin
Italy
- 3A – Rome
- 3B – Cozzo Spadaro
- 4A – Milano
Norway
- 6A – Oslo
Poland
- 5A – Warsaw
Portugal
- 3A – Lisbon
Spain
- 3A – Barcelona
Sweden
- 7 – Kiruna
United Kingdom
- 4A – London
- 5A – Birmingham
Singapore
- 0A – Singapore, Singapore
UAE
- 0B – Dubai
Saudi Arabia
- 1B – Bisha
- 2B – Taif
South America
Argentina
- 2A – San Miguel de Tucuman
- 2B – Santiago del Estero
- 3A – Buenos Aires
- 3B – Mendoza
- 4B – La Quiaca
- 4C – Comodoro Rivadavia
- 5B – Río Gallegos
- 5C – Bariloche
- 6A – Ushuaia
Brazil
- 0A – Salvador
- 0B – Petrolina
- 1A – Rio de Janeiro
- 2A – São Paulo
Chile
- 2A – Isla de Pascua
- 3B – Santiago
- 3C – Concepción
- 4A – Puerto Montt
- 4C – Temuco
- 6A – Punta Arenas
India
- 0A – Mumbai
- 0B – Ahmedabad
- 1A – Hyderabad
- 1B – New Delhi
- 2A – Dehradun
- 2B – Amritsar
- 4A – Srinagar
Hong Kong
- 2A – Hong Kong
Building Vintages
Assets in the tool have either one or two building vintages to choose from, namely, those built or renovated before 2004, 2005-2009, and 2010-2015. The following table describes how the vintages were constructed.
| Region | Vintage Label | PNNL Prototype Label | HVAC Modifications |
| EU & UK | Pre-2004 | PNNL 1980-2004 * | *+ relevant HVAC modifications. See Typical Baseline Systems for HVAC systems per use type. |
| EU & UK | 2004-2009 | PNNL 2010 * | 2004-2009 vintage in EU is assumed to be on par with 2010 PNNL prototype *+ relevant HVAC modifications. See Typical Baseline Systems for HVAC systems per use type. |
| USA & AUS & CAN | Pre-2004 | PNNL 1980-2004 | |
| USA & AUS & CAN | 2004-2009 | PNNL 2004 | |
| Singapore, UAE, and Saudi Arabia | 2004-2009 | PNNL 2004* | *+ relevant HVAC modifications. See Typical Baseline Systems for HVAC systems per use type. |
| Singapore, UAE, and Saudi Arabia | 2010-2015 | PNNL 2010* | *+ relevant HVAC modifications. See Typical Baseline Systems for HVAC systems per use type. |
Column Header Key:
- Region: the country in which the asset is located.
- Vintage Label: the asset's year of original construction or last major renovation
- PNNL Prototype Label: prototype building models developed by the Pacific Northwest National Laboratory (PNNL) have been utilized as typical examples of existing buildings for all typologies.
- HVAC Modifications: notes on variances from the PNNL prototype building models.